| CEMPROOF |
|
|
LIQUID & POWDER INTEGRAL WATER PROOFING COMPOUNDS
|
|
- Resistant to
penetration of water both under:
a. Hydrostatic pressure
b. Capillary action.
- Initially alkaline,
has no corrosive effect on reinforcement in mass concrete
- Is water retentive
and thus aids curing, ensuring maximum strength
- Reduces attack
by water-borne aggressive conditions.
- Improves cohesive
properties of concrete reducing segregation
and bleeding.
- Aids in achieving
better surface finish.
|
|
CEMPROOF Integral
Waterproofer contains a blend of specialized chemicals which when incorporated
in concrete reduces permeability and facilitates the construction of water
tight structures. It makes the concrete waterproof of resist both hydrostatic
pressure and capillary absorption.
|
|
|
Waterproofing Sructures against Ground Water
Pressure
Rendering should be composed of 2-1/2 to 3 parts and sharp sand to 1 part
cement by volume. Add 200ml. (1Kg) CEMPROOF INTEGRAL WATERPROOFER per
50 kgs cement and guage the mix as stiff as possible to reduces to the
minimum the risk of cracking of the rich mix.Never apply a strong mix
on a weak backing.
Apply renderings in two coats at a total thickness of between 20 to 25
mm
(approx. ¾ " to 1")200 ml of Cemproof Integral Waterproofing liquid or
1 kg Cemproof Integral Waterproofing powder should be added to each 50
kg cement (approx. 1 ¾ pts./1 cwt) and the mix should be gauged dry. Apply
the first coat of rendering and extend over floor for a distance of approx.
30 cm.(I foot) from the internal wall floor angle. Scratch to form a key.
Apply the second coat rendering and butt joint to floor forming a cove
at the internal angle. The finishing coat of rendering should be closed
with a steel trowel. It is not possible to apply the first rendering coat
over the total wall area in one day,necessitating the formation of joints,
the joints should be formed at least 60 cm (approx. 2 ft) away from the
internal wall angles ,and in the application of the finishing wall rendering
coat, joints in same should be staggered away from joints in the first
rendering coat .
|
|
| WATER PROOFING MASS CONCRETE |
For normal conditions
mix proportions at 1 part O.P.C , 2 Parts Zone 2 concreting sand to 4
parts coarse agregate plus 200 ml of CEMPROOF INTEGRAL WATERPROOFING LIQUID(1
kg Cem W/P Powder ) per 50 kg of cement. Where water pressure is high
include Cemproof Conflo in a similar mix to increase density taking care
to reduce the water content (water/cement ratio) of the mix. It is absolutely
essential to keep the water content Joints in the concrete should be stepped
and a P.V.C water bar used where appropriately.
|
|
| EXTERNAL WATERPROOFING MASS CONCRETE |
Apply a rendering
18-20 mm (approximately 3/4" thick) in two coats a mix comprising
one part OPC to three parts clean, sharp washed sand adding, CEMPROOF
200ml INTEGRAL WATERPROOFING LIQUID (or 1 kg comproof waterproofing powder)
per 50 kg cement.Use CEMPROOF INTEGRAL WATERPROOF at a rate of 200 ml
(1kg)/50 kg cement. It is possible to scrape finish waterproofed renderings
to minimise any tendency to crack.
|
|